Multimeter Limit 310

Product information
Description
Description

Easy-to-use and ergonomically designed digital multimeter with large clear display. For measuring direct/alternating voltage, DC, resistance and temperature. Plus diode test, continuity test with buzzer, data hold, backlighting and battery capacity warning. Fitted with a rubber cover and fold-out bench support.

Supplied complete with test cables, temperature sensor for max. 260 °C.

Scale length 1999. Safety classification CAT II 250V according to IEC 61010. Fuse protected to max. 250V for 10 seconds and 200mA.

Properties
Properties
Manufacturer´s description
300
ETIM class code
EC000069
Background lit Display
Yes
Max. working temperature
40 °C
Voltage measurement range (AC) max
250 V
Voltage measurement range (AC) min
200 V
Voltage inaccuracy (AC)
± (1.2% +3)
Voltage resolution (AC)
0.1-1 V
Voltage measurement range (DC) max
250 V
Voltage measurement range (DC) min
200 mV
Voltage inaccuracy (DC)
± (0.7% +3)
Voltage resolution (DC)
0.1mV-1V
Current measurement range (DC), max
10 A
Current measurement range (DC), min
2000 µA
Current inaccuracy (DC)
± (1.0% +2)-±(1.0% +5)
Current resolution (DC)
1µA-0.01A
Resistance measurement range, max
20 MΩ
Resistance measurement range, min
200 Ω
Resistance inaccuracy
±(1.0%+2)- ±(1.0%+3)
Resistance resolution
0.1 Ω-0.01 MΩ
Temperature measurement range, max
1000 °C
Temperature measurement range, min
-40 °C
Temperature inaccuracy
-40 to 40 °C: ± 4°C / > 40 to 500 °C: ± (1.0% + 4 °C),
> 500 to 1000 °C: ± (2.0% + 4 °C) / -40 to 104 °F: ± 5 °F,
> 104 to 932 °F: ± (1.5% + 5°F),
> 932 to 1832 °F: ± (2.5% + 5°F)
Temperature resolution
1 °C
Weight
206 g
No. of batteries
2 st
Battery type
Alkaline
Safety classification
CAT II: 250V
Width
77 mm
Length
134 mm
Thickness
47 mm
Battery type ANSI
AAA
Items